What harm will happen if the screw air compressor does not have a temperature control valve? The temperature control valve of the screw air compressor is installed between the machine head and the oil and gas separation barrel, on the edge of the oil filter. The temperature control valve has a total of three oil pipes, one connected to the oil and gas separation barrel, one connected to the oil filter, and one connected to the cooler. When the lubricating oil comes in, according to the level of the oil temperature, the valve core will automatically expand and expand, so that the lubricating oil enters the oil filter filtration or enters the cooler for cooling. If the screw air compressor does not use the temperature control valve and does not install it, what will be the consequences?
What harm will happen if the screw air compressor does not have a temperature control valve? The temperature control valve of the screw air compressor is installed between the machine head and the oil and gas separation barrel, on the edge of the oil filter. The temperature control valve has a total of three oil pipes, one connected to the oil and gas separation barrel, one connected to the oil filter, and one connected to the cooler. When the lubricating oil comes in, according to the level of the oil temperature, the valve core will automatically expand and expand, so that the lubricating oil enters the oil filter filtration or enters the cooler for cooling. If
screw air compressor does not use temperature control valves, omit or does not install, what will be the consequences?
1. The temperature control valve of the air compressor plays the role of constant temperature control, if the lack of temperature control valve will cause the air compressor to jump at high temperature.
2. The temperature control valve is the component that controls the direction of the lubricating oil. If the action is not in place, it may cause the temperature of the unit to be too high or too low.
3. Without a temperature control valve, the temperature of the air compressor lubricating oil will rise after working, and the high-temperature oil will circulate to the lubrication system for continued use, and the oil temperature will continue to rise, accelerating the deterioration of the oil, increasing the load of the equipment, serious friction loss, and shortening the life of the equipment; Increase cooler work, increase electricity consumption, increase operating costs, and waste energy.
If the screw air compressor is not installed with a temperature control valve, it will cause many problems, seriously affecting the performance and working conditions of the air compressor, and the cost required is much larger than the cost of the temperature control valve. What is the correct operation method of the screw air compressor, now follow the editor of Hunan Ruisheng electromechanical equipment to take a look, our official website is
www.hnzega.com.
First, the operator must be familiar with the structure, performance, working principle, operating procedures and precautions of the air compressor.
Second, the operator must undergo technical training and safety training, and after passing the examination, he will take up the post with a certificate, and shall not operate without a certificate.
3. Pre-start inspection:
1. Check the capacity of the lubricating oil in the oil and gas separator, after normal operation, the oil level in the oil level gauge is above the middle of the upper and lower limits.
2. Check whether the gas supply pipeline is dredged, and whether all bolts and joints are tightened.
3. Check whether the various instrument indications on the low-voltage distribution cabinet are correct, whether the electrical wiring is intact, and whether the grounding wire meets the standard.
4. When testing, about 0.5 liters of lubricating oil should be added from the air intake, and rotated by hand for several turns or jogging a few times to prevent the loss of oil in the compressor when starting, and pay special attention not to let foreign objects fall into the body to avoid damage to the compressor.
5. Before starting, the compressor exhaust valve should be opened, the manual sewage valve should be closed, and the operator should be in a safe position.