"Air compressor is a general mechanical equipment, now widely used in various fields, air compressor due to motor power and the length of the main shaft, the exhaust will be large, the following ZEGA boring on the customer proposed air compressor exhaust insufficient phenomenon to do a simple analysis. ”
First, the selection is too small
Many users have just begun to know the specific gas consumption of their production, on the approximate selection, at this time the exhaust pressure does not come up, lower than the rated exhaust pressure, can not meet the normal gas consumption of the factory, at this time, you can check whether the pipeline has a leakage point. Close the valve behind the air tank, if the unit can quickly increase the pressure, open the valve, the pressure drops quickly, and finally at a pressure point, this can confirm that the selection of the air compressor unit is too small, and the exhaust volume of the unit is less than the actual gas consumption of production.
Solution: Add a new unit, so that the exhaust volume of the air compressor is greater than the air consumption by 10-20% is the most scientific.
Second, whether to add gas equipment< br/>
After the air compressor unit is used for a period of time, the gas volume is obviously not enough, the pressure cannot come up, and it is maintained at the downline position of the rated gas. At this time, you should first check whether there is a new gas equipment, if there is a new gas equipment, what is the amount of gas, compare the air compressor unit to see if it can meet the requirements, if not, please and the new air compressor unit, increase the exhaust volume.
If there is no new gas equipment, the exhaust volume is still not enough, first check the leakage of the pipeline, if the pipeline does not have a leakage point, it is the problem of the air compressor itself.
The insufficient exhaust volume of the air compressor itself has the following problems:
1. Whether the maintenance is timely< br/>
Air compressor exhaust volume decreased, after excluding the above possibilities, first look at whether the air compressor has been maintained, how long has it been maintained, if the environment is not very ideal, the air compressor should be checked for 2000 hours to check whether the air filter is blocked, light can use compressed air to remove dust, the blockage is serious, replace the new air filter.
Many times, the exhaust volume of the air compressor decreases, there is no big problem, that is, the customer neglects maintenance, the air compressor air filter is blocked, and after replacing the new air filter, it is used normally.
In addition, in addition to the air filter, the lubricant and other filter elements are also critical, check whether the lubricant is within the standard range, if missing, please add it appropriately.
2. Whether the intake valves are all open
The exhaust volume of the air compressor drops, check the unit, just maintain, eliminate the three filters and oil problems, this is to first check the air compressor intake valve, remove the intake hose, open the air compressor, and watch whether the opening of the intake valve is normal. The theoretical design service life of the intake valve is 100,000 actions, because each manufacturer uses different brand batches, and the quality is also different, so the failure of the intake valve may lead to a decrease in the exhaust volume of the unit.
If the intake valve cannot be fully opened when the air compressor is loaded, it can be concluded that the decrease in exhaust volume is a failure of the intake valve, and it should be removed for maintenance or replaced.