What should I do if the compressed air of ZEGA screw air compressor contains water?
When many companies choose ZEGA screw air compressors, in order to save costs, they do not configure corresponding after-treatment equipment, so water will appear in the compressed air. But there are also users after listening to the guidance of the sales staff, purchased the corresponding gas tank, refrigeration dryer and desiccant, etc., or there will be water out, what is the matter?
Many companies are buying < a href="http://www.hnzega.com/industrytrends.html" > ZEGA screw air compressor, in order to save costs, there is no corresponding after-treatment equipment, so water will appear in the compressed air. But there are also users after listening to the guidance of the sales staff, purchased the corresponding gas tank, refrigeration dryer and desiccant, etc., or there will be water out, what is the matter?
For some industries, the quality requirements for compressed air are very high, what is the reason for the water in the compressed air? How to solve it?
1. The air humidity around the air compressor station is large. The air itself has humidity, contains a certain amount of moisture, when the air is compressed, due to the high internal temperature of the compressor, the moisture directly evaporates to form water vapor, and then discharges the compressor with the pressure, and when the shutdown, the temperature drops, which will make the water vapor form condensate. Therefore, the working environment humidity of the air compressor should be low; Or drain this condensate before start-up use.
2. Post-treatment drying equipment fails. The general refrigeration dryer processing capacity after drying is a pressure dew point of 3 °C, if your work site temperature is lower than 3 °C, there will inevitably be water. At this time, it is recommended to configure micro-thermal suction dryer post-treatment drying equipment, and the pressure dew point can reach -20 °C without producing water in it.
3. The capacity of the configured post-treatment drying equipment is not enough. Generally speaking, the drying post-treatment amount configured by the manufacturer for the user is configured according to the average air consumption, if your instantaneous air consumption is large, it will cause the capacity of the post-treatment drying equipment to be insufficient, resulting in water in the gas.
4. The gas tank itself has the function of stagnant water, which contains a large amount of water that is not discharged and forgets to drain. Periodically open the drain valve under the gas tank to drain the water.
5. There is a problem with the piping design. The design slope of the compressed air pipeline is not enough, and the condensate discharge of the pipeline is not timely, which will cause water.
Usually, we must also pay attention to the maintenance of ZEGA screw air compressor and after-treatment equipment. Compressed air contains water, there must be a problem with the compressed air system, in the use of the air compressor, to do a good job of maintenance. This protects your gas equipment to a great extent. If you have further questions, feel free to contact ZEGA Boring and we will solve your problems.